This product is suitable for control, monitoring circuit and protection circuit with AC rated voltage of 450/750V and below. Its mechanical and physical properties. Electrical performance meets the requirements of GB/T9330.2- -2008 "plastic insulation control cable"
Use characteristics and main electrical performance indicators
1. The laying temperature of the cable is ≥ 0 °C;
2. The long-term allowable operating temperature of the cable conductor is 70 ° C;
3. Minimum allowable bending radius;
a. Untwisted cable shall be not less than 6 times the outer diameter of the cable.
b: Cables with armor or copper tape shielding structure shall be not less than 12 times the outer diameter of the cable.
c: The flexible cable with shielding structure should be no less than 6 times the outer diameter of the cable.
4. The finished cable can withstand AC 50Hz, 3000V, 5min withstand voltage test without breakdown.
5. The conductor DC resistance complies with the GB/T3956-2008 "Conductors for Cables" standard.
This product is used for 0.6/1KV and below control, monitoring circuit and protection circuit. Its mechanical and physical properties and electrical performance are in accordance with GB/T9330.3-2008 "Plastic insulation control cable part 3 XLPE insulated control cable" standard .
Use characteristics and main electrical performance indicators
1. Cable laying temperature ≥ 0 ° C:
2. The long-term allowable operating temperature of the cable conductor is 90 °C:
3. Minimum allowable bending radius:
a. The armored cable shall be not less than 8 times the outer diameter of the cable.
b. Cable with armor or copper tape shielding structure. It should be no less than 12 times the outer diameter of the cable.
c. The flexible cable with shielding structure should be no less than 6 times the outer diameter of the cable.
4. The finished cable can withstand AC 50Hz.3. 5KV.5min withstand voltage test without breakdown.
5. Conductor DC resistance is in accordance with GB/T3956--2008 "Conductor for Cable" standard.
Online Message

Qilu Cable Co., Ltd.
Tel:+86-400-891-6689
Tel:+86-0635-2157666
Tel:+86-0635-2158888
E-mail : qldl8888@163.com
Address : No. 389, Huanghe West Road, Yanggu County, Shandong Province

Cell Phone Station

No public
Copyright @ 2022 Qilu Cable Co., Ltd. 鲁ICP备18023738号-1